Torque Tester for Screwed Glands is designed to perform torque tests of screwed glands according to EN / IEC 60598-1 clause 4.12.5. Test Procedure Screwed glands shall be fitted with a cylindrical metal rod having a diameter equal to the nearest whole number of millimetres below the internal diameter of the packing. The glands shall then be tightened by means of a suitable spanner, the moment shown in Table 4.2 being applied to the spanner for 1 min. Technical Parameters: Stainless steel bar: Ф 5, Ф 7, Ф 9, Ф 10, Ф 12, Ф 14, Ф 16, Ф 18, Ф 20, Ф 22, Ф 25, Ф 30, Ф 32, Ф 40 mm; Mass: 20N, 40N, 50N, 60N; hook weights: 20N and 6N Wheel diameter: 250 mm, wooden Diameter of test rod mm Moment Metal glands (Nm) Moulded plastic glands (Nm) < 7 6.25 2.5 7 ~ 14 6.25…